Inverter Power Inverter 2000w 3000w

Inverter Power Inverter 2000w 3000w

W9 series inverter power inverter 2000w 12v 24v 48v, 3000w 24v 48v invert to 110v 120v 220v 230v 240v, 50Hz or 60Hz automatic recognition.

Special voltage and power can be customized.

Description

⌈ Feature ⌋

  1. Inverter power inverter pure sine wave output;
  2. AC charge current 0-30A adjustable;
  3. Air-cooled type radiator, great energy-saving effect;
  4. Strong loading capacity; Peak power more than 3 times;
  5. Working modes: AC first, battery first, energy-saving;
  6. RS232 communication port optional.
  7. Perfect protection system: Battery undervoltage, battery overvoltage, overload power, output short circuit, temperature

 

⌈ Technical Parameters ⌋

Model W920212/24/4830224/48
Rated Power2000W3000W
Peak Power(20ms)6000W9000W
Start Motor2HP3HP
Battery Voltage12/24V/48VDC24/48VDC
Size(L*W*Hmm)530*245*215
Packing Size(L*W*Hmm)590*300*270
N.W.(kg)2428
G.W.(kg)(Carton Packing)2731
InputDC Input Voltage Range10.5-15VDC(Single battery voltage)
AC Input Voltage Range85VAC~138VAC / 170VAC~275VAC
AC Input Frequency Range45Hz~65Hz
Max AC charging current30A/25A/15A30A/20A
AC charging methodThree-stage (constant current, constant voltage, floating charge)
OutputEfficiency(Battery Mode)≥85%
Output Voltage(Battery Mode)110VAC±2%/ 220VAC±2%
Output Frequency(Battery Mode)50/60Hz±1%
Output Wave(Battery Mode)Pure Sine Wave
Efficiency(AC Mode)>99%
Output Voltage(AC Mode)110VAC±10% / 115VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Output Frequency(AC Mode)Tracking Automatically
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode)≤2.5% rated power
No load loss(AC Mode)≤2% rated power( charger does not work in AC mode)
No load loss(Energy saving Mode)≤10W
ProtectionBattery undervoltage alarm11V(Single battery voltage)
Battery undervoltage protection10.5V(Single battery voltage)
Battery overvoltage alarm15V(Single battery voltage)
Battery overvoltage protection17V(Single battery voltage)
Battery overvoltage recovery voltage14.5V(Single battery voltage)
Overload power protectionAutomatic protection (battery mode), circuit breaker or insurance (AC mode)
Output short circuit protectionAutomatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection>90°C(Shut down output)
AlarmANormal working condition, buzzer has no alarm sound
BBuzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
CWhen the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal.
Battery type
(Optional)
U0: Gel U.S.ACharge Voltage:14V;Float Voltage:13.7V(Single battery voltage)
U1: A.G.M.1Charge Voltage:14.1V;Float Voltage:13.4V(Single battery voltage)
U2:  A.G.M.2Charge Voltage:14.6V;Float Voltage:13.7V(Single battery voltage)
U3: Sealed lead AcidCharge Voltage:14.4V;Float Voltage:13.6V(Single battery voltage)
U4: Gel EuropeanCharge Voltage:14.4V;Float Voltage:13.8V(Single battery voltage)
U5: Open lead AcidCharge Voltage:14.8V;Float Voltage:13.5V(Single battery voltage)
U6: Calcuim(open)Charge Voltage:15.1V;Float Voltage:13.6V(Single battery voltage)
U7: Sulphation cycle15.5V for 4hrs
customize batteryCharge and discharge parameters of different types of batteries (such as lithium batteries, etc.)
can be customized according to user requirements.
EnvironmentOperating temperature-10℃~40℃
Storage temperature-15℃~60℃
Noise≤55dB
Elevation2000m(More than derating)
Humidity0%~95% ,No condensation

 

 

⌈ Wiring Diagram ⌋

 

⌈ Application ⌋

Get all the latest information on Events, Sales and Offers.

has been added to your cart: