TYN Solar Generator Cabinet with Inverter Controller Battery 3KW 5KW 6KW 48V/96V
- Pure sine wave output;
- AVR function, AC charge;
- LCD integration display;
- AC first and battery first optional;
- Inverter, controller and battery are all in one cabinet;
- Protection: Low voltage, over voltage, short circuit, over load and over temperature etc.
- Description
- Inquiry
Description
⌈Application Area⌋
Office and public facilities, household system, network transmission equipment, manufacturing, control system, solar energy system, oil field, drilling field operation, etc.
Provide stable reliable and safe solutions for families, islandsships and other small photovoltaic power system.
⌈Technical Parameters⌋
Model TYN | 30248/96 | 50248/96 | 60248/96 | |
Rated Power | 3000W | 5000W | 6000W | |
Peak Power(20ms) | 9000W | 15000W | 18000W | |
Start Motor | 3HP | 4HP | 4HP | |
Battery Voltage | 48/96VDC | |||
Inside Battery Capacity | 200Ah*4/100Ah*8 | |||
Size(L*W*Hmm) | 742*520*1080 | |||
Package Size (L*W*Hmm) | 780*620*1400 | |||
N.W.(kg) Without Battery | 83 | 95 | 97 | |
G.W.(kg) Without Battery Carton Packing | 101 | 113 | 115 | |
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | ||
AC Input Voltage Range | 73VAC~138VAC / 145VAC~275VAC | |||
AC Input Frequency Range | 45Hz~65Hz | |||
Max AC charging current | 6A~15A (Depending on the model) | |||
AC charging voltage | LEAD battery:Charge Voltage :14V; Float Voltage:13.8V(Single battery voltage) | |||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | |||
Output | Efficiency(Battery Mode) | ≥85% | ||
Output Voltage(Battery Mode) | 110VAC±2% / 220VAC±2% | |||
Output Frequency(Battery Mode) | 50/60Hz±1% | |||
Output Wave(Battery Mode) | Pure Sine Wave | |||
Efficiency(AC Mode) | >99% | |||
Output Voltage(AC Mode) | 110VAC±10% / 220VAC±10% | |||
Output Frequency(AC Mode) | Tracking Automatically | |||
Output waveform distortion(Battery Mode) | ≤3%(Linear load) | |||
No load loss(Battery Mode) | ≤1% rated power | |||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | |||
No load loss(Energy saving Mode) | ≤10W | |||
Battery Type | Customize battery | Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements | ||
Alarm | A | Normal working condition, buzzer has no alarm sound | ||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | |||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | |||
Inside Solar controller (Optional) | Charging Mode | MPPT or PWM | ||
Charging current | 48V system: 10A/20A/30A/40A/50A/60A; 96V system: 50A/100A(PWM) | |||
PV Input Voltage Range | PWM: 60V-88V(48V system); 120V-170V(96V system) / MPPT: 60V-120V(48V system) | |||
Max PV Input Voltage(At 25℃) | PWM: 100V(48V system); 200V(96V system) / MPPT: 150V(48V system) | |||
PV Array Maximum Power | 48V System: 560W/1120W/1680W/2240W/2800W/3360W; 96V System: 5.6KW/11.2KW | |||
Standby loss | ≤3W | |||
Maximum conversion efficiency | >95% | |||
Environment | Operating temperature | -10℃~40℃ | ||
Storage temperature | -15℃~60℃ | |||
Noise | ≤55dB | |||
Elevation | 2000m(More than derating) | |||
Humidity | 0%~95% ,No condensation |
⌈System Application Diagram⌋