DC/AC Inverter with Solar Charger 12V 220V 1000W-7000W
1000W/1500W/2000W DC12V/24V/48V
3000W/4000W DC24V/48V
5000W/6000W DC48V
Output Voltage: AC110V/120V/220V/230V/240V
Frequency: 50Hz/60Hz
Wave Form: Pure Sine Wave
AC Charger: 0-30A
Can Be Customized for Special Power and Voltage and Appearance
- Description
- Inquiry
Description
⌈Inverter Introduction⌋
1. EI low frequency transformer,strong impact resistance;
2. Dedicated micro-processing chip design, equipment operation speed is faster and more stable;
3. LCD display,real-time view of setting parameters and operating status;
4. AC charging current 0~30A adjustable,battery configurations are more flexible by users;
5. Three working modes(AC first,battery first,energy-saving mode);
6. Equipped with stable voltage and frequency output, stronger load compatibility;
7. Perfect all-round automatic protection function, stable and reliable performance;
8. Perfect fault code query function, convenient for users to monitor the running status in real time;
9. Support diesel or petrol generators,adapt to any tough electricity environment;
10. RS485 communication port/APP optional.
⌈Inverter Details⌋
⌈Inverter How to Use⌋
⌈Inverter Installation⌋
⌈Inverter Parameters⌋
Specification | |||||||||
Model DA | 10212/24/48 | 15212/24/48 | 20212/24/48 | 30224/48 | 40224/48 | 50248 | 60248 | 70248 | |
Rated Power | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | 7000W | |
Peak Power(20ms) | 3000VA | 4500VA | 6000VA | 9000VA | 12000VA | 15000VA | 18000VA | 21000VA | |
Start Motor | 1HP | 1.5HP | 2HP | 3HP | 3HP | 4HP | 4HP | 5HP | |
Battery Voltage | 12/24/48VDC | 12/24/48VDC | 24/48VDC | 24/48VDC | 48VDC | ||||
Size(L*W*Hmm) | 485*262*181 | 525*292*206 | |||||||
Packing Size(L*W*Hmm) | 580*310*240 | 620*340*265 | |||||||
N.W.(kg) | 16 | 18 | 20 | 23 | 40 | 43 | 46 | 48 | |
G.W.(kg)(Carton Packing) | 18 | 20 | 22 | 25 | 43 | 46 | 49 | 51 | |
Installation Method | Wall-Mounted |
<< Slide left for more parameters
Parameter | |||||||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | |||||||
AC Input Voltage Range | 85VAC~138VAC(110VAC) / 95VAC~148VAC(120VAC) / 170VAC~275VAC(220VAC) / 180VAC~285VAC(230VAC) / 190VAC~295VAC(240VAC) | ||||||||
AC Input Frequency Range | 45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz) | ||||||||
Max AC charging current | 0~30A(Depending on the model) | ||||||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | ||||||||
Output | Efficiency(Battery Mode) | ≥85% | |||||||
Output Voltage(Battery Mode) | 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | ||||||||
Output Frequency(Battery Mode) | 50/60Hz±1% | ||||||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||||||
Efficiency(AC Mode) | >99% | ||||||||
Output Voltage(AC Mode) | 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10% | ||||||||
Output Frequency(AC Mode) | Tracking Automatically | ||||||||
Output waveform distortion (Battery Mode) | ≤3%(Linear load) | ||||||||
No load loss(Battery Mode) | ≤2.5% rated power | ||||||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | ||||||||
No load loss(Energy saving Mode) | ≤10W | ||||||||
Battery Type | VRLA Battery | Charge Voltage :14.2V; Float Voltage:13.8V( 12V system; 24V system x2 ; 48V system x4) | |||||||
Customize battery | Charging and discharging parameters of different types of batteries can be customized according to user requirements (charging and discharging parameters of different types of batteries can be set through the operation panel) | ||||||||
Protection | Battery undervoltage alarm | Factory default: 11V(12V system; 24V system x2; 48V system x4) | |||||||
Battery undervoltage protection | Factory default: 10.5V(12V system; 24V system x2; 48V system x4) | ||||||||
Battery overvoltage alarm | Factory default: 15V(12V system; 24V system x2; 48V system x4) | ||||||||
Battery overvoltage protection | Factory default: 17V(12V system; 24V system x2; 48V system x4) | ||||||||
Battery overvoltage recovery voltage | Factory default: 14.5V(12V system; 24V system x2; 48V system x4) | ||||||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||
Temperature protection | >90°C(Shut down output) | ||||||||
Alarm | A | Normal working condition, buzzer has no alarm sound | |||||||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | ||||||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | ||||||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||||||
Transfer Time | ≤4ms | ||||||||
Display | LCD | ||||||||
Thermal method | Cooling fan in intelligent control | ||||||||
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | ||||||||
Environment | Operating temperature | -10℃~40℃ | |||||||
Storage temperature | -15℃~60℃ | ||||||||
Noise | ≤55dB | ||||||||
Elevation | 2000m(More than derating) | ||||||||
Humidity | 0%~95% ,No condensation | ||||||||
Note: All specifications are subject to charge without prior notice |
⌈Why Choose Xindunpower⌋
⌈About Xindunpower – Solar Inverter Manufacturer⌋
⌈Factory Scene⌋
⌈Our Certificate⌋
⌈Global Solar Power Expo⌋
If you are interested in this DA series inverter, please feel free to contact us through the contact information below.
Xindun is a solar power factory in China, now we are looking for sales agents all over the world, wating for you to join us.