24V/240 Volt Solar Hybrid Inverter Pure Sine Wave Inverter 700W-40KW
700W/1000W DC12V/24V
1500W/2000W/3000W DC24V/48V
3500W/4000W/5000W/6000W DC48V/96V
7000W/8000W/10KW DC48V/96V/192V
12KW DC96V/192V
15KW/20KW DC192V
25KW/30KW DC240V
40KW DC384V
Output Voltage: AC110V/120V/220V/230V/240V
Frequency: 50Hz/60Hz
Wave Form: Pure Sine Wave
Solar Controller: MPPT/PWM Built-in Solar Inverter
AC Charger: 0-20A
Can Be Customized for Special Power and Voltage and Appearance
- Description
- Inquiry
Description
⌈Inverter Feature⌋
1. Pure sine wave output;
2. High efficiency toroidal transformer lower loss ;
3. Intelligent LCD integration display;
4. AC charge current 0-20A adjustable; battery capacity configuration more flexible;
5. Three types working modes adjustable:AC first, DC first, energy-saving mode;
6. Frequency adaptive function, adapt to different grid environments;
7. Built-in PWM or MPPT controller optional;
8. Added fault code query function,facilitate user to monitor the operation state in real time;
9. Supports diesel or gasoline generator, adapt any tough electricity situation;
10. RS485 communication port/APP optional.
⌈Inverter Models⌋
Inverter 700W/1000W/1500W 12V/24V/48V:
Inverter 2000W/3000W/3500W 24V/48V/96V:
Inverter 4000W/5000W/6000W/7000W 48V/96V/192V:
Inverter 8KW/10KW/12KW 48V/96V/192V:
Inverter 15KW/20KW/25KW 192V/240V:
Inverter 30KW/40KW 240V/384V:
⌈Inverter How to Use⌋
Here I introduce three common working modes of inverter:
1) AC priority mode(d1)
When the grid electricity is normal (in line with the grid electricity input voltage range of the inverter), the grid electricity charge battery (if with built-in solar cotroller, the grid electricity and PV charge the battery simultancously); on the other hand, the grid electricity supplies stable power to the loads after sabilization. (the load do not consume PV and battery energy);
When the grid electricity is abnormal(the grid electricity exceeds the working range of the inverer or the grid electricity supply is inrupted), the loads will be powered by the battery (if with built-in controller, when PV power rate is larger than the loads, PV will power the loads and the surplus energy will charge the bttery; when PV power rate is less than the loads, the deficiency will be made up by battery, so both PV and battery will power the loads).
2) Battery (PV) priority mode(d3)
When the battery is fully charged (like single- cell battery voltage is up to 13.2VDC), even the grid electricity is normal, the loads will be powered by the battery (if with built-in controller, when PV power rate is larger than that of the loads, PV will fully powers the loads and the surplus energy will charge the battery; when PV power rate is less than the loads, the deficiency will be made up by battery, so both PV and battery will power the loads);
When the battery is in low voltage (the voltage of regular single-cell battery is 11VDC) and the grid electricity is normal, the inverter will switch to AC priority mode. The grid electricity supplies power to the load after stabilization, and the grid electricity charges battery simultaneously (if with built-in controller, PV and the grid electricity charge the battery simultaneously. The loads do not consume the energy of PV and battery).
Remarks: Under AC Priority Mode/ Battery Priority Mode, when the grid electricity charging current is not set as 0A, the grid electricity charge battery; when the grid electricity charging current is set to 0A, the grid electricity does not charge battery, but the solar controller charges the battery.
3) Energy saving mode(d2)
Inverter works under the battery mode, once the load capacity is less than 10% of the inverter rated power, the inverter will start and stop regularly to achieve energy saving effect (ie: the machine will intermittently interrupt the inverter output); When the load is greater than 10% of the inverter rated power, the inverter will out of this energy saving mode.
⌈Inverter Details⌋
⌈Inverter Installation⌋
⌈Inverter Parameters⌋
Specification | |||||||||||
Model WD | 70112/24 | 10212/24 | 15224/48 | 20224/48 | 30224/48 | 35248/96 | 40248/96 | 50248/96 | 60248/96 | 70248/96/192 | |
Rated Power | 700W | 1000W | 1500W | 2000W | 3000W | 3500W | 4000W | 5000W | 6000W | 7000W | |
Peak Power(20ms) | 2100VA | 3000VA | 4500VA | 6000VA | 9000VA | 10500VA | 12000VA | 15000VA | 18000VA | 21000VA | |
Start Motor | 0.5HP | 1HP | 1.5HP | 2HP | 3HP | 3HP | 3HP | 4HP | 4HP | 5HP | |
Battery Voltage | 12/24VDC | 12/24VDC | 24/48VDC | 24/48VDC | 24/48VDC | 48/96VDC | 48/96VDC | 48/96VDC | 48/96VDC | 48/96/192VDC | |
Max AC charging current | 0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power) | ||||||||||
Built-in solar controller charging current (optional) | 10A~60A(PWM or MPPT) | 24/48V(PWM:10A~60A/MPPT:10A~100A) | 48V(PWM:10A~120A/MPPT:10A~100A) / 96V(50A/100A(PWM or MPPT)) | ||||||||
Size(L*W*Hmm) | 340x165x283 | 410x200x350 | 491x260x490 | ||||||||
Packing Size(L*W*Hmm) | 405x230x340(1pc) / 475x415x350(2pc) | 475x265x410 | 545x315x550 | ||||||||
N.W.(kg) | 9.5(1pc) | 10.5(1pc) | 11.5(1pc) | 17 | 20.5 | 21.5 | 29 | 30 | 31.5 | 36 | |
G.W.(kg) | 11(1pc) | 12(1pc) | 13(1pc) | 19 | 22.5 | 23.5 | 32 | 33 | 34.5 | 39 | |
Installation Method | Tower | ||||||||||
Model WD | 80248/96/192 | 10348/96/192 | 12396/192 | 153192 | 203192 | 253240 | 303240 | 403384 | |||
Rated Power | 8KW | 10KW | 12KW | 15KW | 20KW | 25KW | 30KW | 40KW | |||
Peak Power(20ms) | 24KVA | 30KVA | 36KVA | 45KVA | 60KVA | 75KVA | 90KVA | 120KVA | |||
Start Motor | 5HP | 7HP | 7HP | 10HP | 12HP | 15HP | 15HP | 20HP | |||
Battery Voltage | 48/96/192VDC | 48/96V/192VDC | 96/192VDC | 192VDC | 192VDC | 240VDC | 240VDC | 384VDC | |||
Max AC charging current | 0A~40A(Depending on the model,The maximum charging power is 1/4 of the rated power) | 0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power) | |||||||||
Built-in solar controller charging current (optional) | PWM:(48V:120A;96V:50A/100A;192V/384V:50A) MPPT:(48V:100A/200A;96V:50A/100A;192V/384V:50A) | 50A/100A | 50A/100A | ||||||||
Size(L*W*Hmm) | 540x350x695 | 593x370x820 | 721x400x1002 | ||||||||
Packing Size(L*W*Hmm) | 600*410*810 | 656*420*937 | 775x465x1120 | ||||||||
N.W.(kg) | 66 | 70 | 77 | 110 | 116 | 123 | 167 | 192 | |||
G.W.(kg) | 77 | 81 | 88 | 124 | 130 | 137 | 190 | 215 | |||
Installation Method | Tower |
<< Slide left for more parameters
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | |||||||||
AC Input Voltage Range | 700W~7000W: 73VAC~138VAC(110VAC) / 83VAC~148VAC(120VAC) / 145VAC~275VAC(220VAC) / 155VAC~285VAC(230VAC) / 165VAC~295VAC( 240VAC) 8KW~40KW: | ||||||||||
AC Input Frequency Range | 45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz) | ||||||||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | ||||||||||
Output | Efficiency(Battery Mode) | ≥85% | |||||||||
Output Voltage(Battery Mode) | 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | ||||||||||
Output Frequency(Battery Mode) | 50Hz±0.5 or 60Hz±0.5 | ||||||||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||||||||
Efficiency(AC Mode) | >99% | ||||||||||
Output Voltage(AC Mode) | Follow input | ||||||||||
Output Frequency(AC Mode) | Tracking Automatically | ||||||||||
Output waveform distortion (Battery Mode) | ≤3%(Linear load) | ||||||||||
No load loss(Battery Mode) | ≤1% rated power | ||||||||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | ||||||||||
No load loss (Energy saving Mode) | ≤10W | ||||||||||
Battery Type (selectable) | VRLA Battery | Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage) | |||||||||
Customize battery | Charging and discharging parameters of different types of batteries can be customized according to user requirements (charging and discharging parameters of different types of batteries can be set through the operation panel) | ||||||||||
Protection | Battery undervoltage alarm | Factory default: 11V(Single battery voltage) | |||||||||
Battery undervoltage protection | Factory default: 10.5V(Single battery voltage) | ||||||||||
Battery overvoltage alarm | Factory default: 15V(Single battery voltage) | ||||||||||
Battery overvoltage protection | Factory default: 17V(Single battery voltage) | ||||||||||
Battery overvoltage recovery voltage | Factory default: 14.5V(Single battery voltage) | ||||||||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||||
Temperature protection | >90°C(Shut down output) | ||||||||||
Alarm | A | Normal working condition, buzzer has no alarm sound | |||||||||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | ||||||||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | ||||||||||
Inside Solar controller (Optional) | Charging Mode | PWM or MPPT | |||||||||
PV Input Voltage Range | PWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system); 120V-176V(96V system);240V-352V(192V system) ;300V-400V(240V system); 480V-704V(384V system) MPPT: 15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system); 120V-240V(96V system);240V-360V(192V system);300V-400V(240V system);480V-640V(384V system) | ||||||||||
Max PV Input Voltage(Voc) (At the lowest temperature) | PWM: 50V(12V/24V system); 100V(48V system); 200V(96V system);400V(192V system);500V(240V system) ;750V(384V system) MPPT: 150V(12V/24V/48V system); 300V(96V system);450V(192V system);500V(240V system) ;800V(384V system) | ||||||||||
PV Array Maximum Power | 12V system: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A)/1120W(80A)/1400W(100A); 24V system: 280W(10A)/560W(20A)/840W(30A)/1120W(40A)/1400W(50A)/1680W(60A)/2240W(80A)/2800W(100A); 48V system: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A)/6720W(PWM 120A)/5.6KW&11.2KW(MPPT 100A/200A); 96V system: 5.6KW(50A)/11.2KW(100A); 192V system: (PWM:11.2KW(50A)/22.4KW(100A)) / (MPPT:11.2KW(50A)/11.2*2KW(100A)); 240V system: (PWM:14KW(50A)/28KW(100A)) / (MPPT:14KW(50A)/14*2KW(100A)); 384V system: (PWM:22.4KW(50A)/44.8KW(100A)) / (MPPT:22.4KW(50A)/22.4*2KW(100A)) | ||||||||||
Standby loss | ≤3W | ||||||||||
Maximum conversion efficiency | >95% | ||||||||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||||||||
Transfer Time | ≤4ms | ||||||||||
Display | LCD | ||||||||||
Thermal method | Cooling fan in intelligent control | ||||||||||
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | ||||||||||
Environment | Operating temperature | -10℃~40℃ | |||||||||
Storage temperature | -15℃~60℃ | ||||||||||
Noise | ≤55dB | ||||||||||
Elevation | 2000m(More than derating) | ||||||||||
Humidity | 0%~95% ,No condensation | ||||||||||
Note: All specifications are subject to charge without prior notice |
⌈Why Choose Xindunpower⌋
⌈About Xindunpower – Solar Inverter Manufacturer⌋
⌈Inverter Factory Scene⌋
⌈Our Certificate⌋
⌈Global Solar Power Expo⌋
If you are interested in this WD series inverter, please feel free to contact us through the contact information below.
Xindun is a solar power factory in China, now we are looking for sales agents all over the world, wating for you to join us.